EN
Sensitive electrochemical determination of Cefpirome in human urine using differential pulse voltammetry
Abstract
Cefpirome, which is a fourth-generation cephalosporin, was analyzed for the first time at a glassy carbon electrode using differential pulse voltammetry in this novel method. Different experimental conditions were optimized, such as pH and electrolyte type, to achieve a high peak current. Under the optimum conditions, the oxidation of cefpirome exhibited diffusion-controlled process depending on pH. Cefpirome was electrochemically determined at the linear range between 2-200 µM, and the detection limit was found as 0.167 µM in pH 4.7 acetate buffer solution. Analysis results showed that the proposed electrochemical method could be used for the determination of cefpirome in human urine samples. A linear relationship has been obtained in the concentration range of 2-10 µM. At the same time, the detection limit was found as 0.101 µM for cefpirome in human urine. Moreover, to check the selectivity of the proposed method, the effect of some interference species, including ascorbic acid, uric acid, dopamine, glucose, 〖"Na" 〗^"+" , "K" ^"+" , 〖"Ca" 〗^"+2" , 〖"NO" 〗_"3" ^"-" , have also been investigated. As a result, a simple, sensitive, reproducible, no time-consuming, and more environmentally friendly method was developed when compared to the literature studies.
Keywords
Supporting Institution
Ankara University
Project Number
18B0237001
Thanks
The authors would like to thank the Ankara University Scientific Research Projects Commission for financial support (Project No: 18B0237001).
References
- [1] Nawaz M., Arayne M. S., Sultana N., Abbas H. F., Investigation of interaction studies of Cefpirome with ACE-Inhibitors in various buffers, Spectrochim. Acta - Part A Mol. Biomol. Spectrosc., 137 (2015) 1050–1054.
- [2] Kong X. X., Jiang J. L., Qiao B., Liu H., Cheng J. S., Yuan Y. J., The biodegradation of Cefuroxime, Cefotaxime and Cefpirome by the Synthetic Consortium with Probiotic Bacillus Clausii and investigation of their potential biodegradation pathways, Sci. Total Environ., 651 (2019) 271–280.
- [3] Zalewski P., Skibiński R., Szymanowska-Powałowska D., Piotrowska H., Kozak M., Pietralik Z., Bednarski W., Cielecka-Piontek J., The Radiolytic Studies of Cefpirome Sulfate in the solid state, J. Pharm. Biomed. Anal., 118 (2016) 410–416.
- [4] Jain R., Vikas, Voltammetric Determination of Cefpirome at Multiwalled Carbon Nanotube modified Glassy Carbon Sensor based electrode in bulk form and Pharmaceutical formulation, Colloids Surfaces B. Biointerfaces, 87(2) (2011) 423–426.
- [5] Hong Y. H., Xu X. L., Li W. Q., Xu B. Z., Wu H. Q., Cheng Y., Chen H., Zhang B. S., Zhang F., A high-accuracy screening method of 44 Cephalosporins in meat using liquid Chromatography Quadrupole-Orbitrap hybrid mass spectrometry, Anal. Methods, 9(46) (2017) 6534–6548
- [6] Li W., Shen H., Hong Y., Zhang Y., Yuan F., Zhang F., Simultaneous determination of 22 Cephalosporins drug residues in Pork Muscle using liquid Chromatography-Tandem mass spectrometry, J. Chromatogr. B. Anal. Technol. Biomed. Life Sci., 1022 (2016) 298–307.
- [7] Zalewski, P., Skibiński R., Cielecka-Piontek J., Bednarek-Rajewska K., Development and validation of stability-indicating HPLC method for determination of Cefpirome Sulfate, Acta Pol. Pharm., 71(5) (2014) 731-736.
- [8] Breilh D., Lavallee C., Fratta A., Ducint D., Cony-Makhoul P., Saux M. C., Determination of Cefepime and Cefpirome in human serum by high-performance liquid Chromatography using an ultrafiltration for antibiotics serum extraction, J. Chromatogr. B Biomed. Sci. Appl., 734(1) (1999) 121–127.
Details
Primary Language
English
Subjects
-
Journal Section
Research Article
Publication Date
September 24, 2021
Submission Date
March 21, 2021
Acceptance Date
July 4, 2021
Published in Issue
Year 1970 Volume: 42 Number: 3
APA
Erkmen, C., Bozal Palabıyık, B., & Uslu, B. (2021). Sensitive electrochemical determination of Cefpirome in human urine using differential pulse voltammetry. Cumhuriyet Science Journal, 42(3), 593-601. https://doi.org/10.17776/csj.900483
Cited By
Electroanalytic properties of unmodified and modified solid contact potentiometric β-lactam sensors in aqueous and biological media
Industrial laboratory. Diagnostics of materials
https://doi.org/10.26896/1028-6861-2022-88-6-15-24Modified planar sensors for cefepime determination
Industrial laboratory. Diagnostics of materials
https://doi.org/10.26896/1028-6861-2023-89-3-5-13