Abstract

Cooling towers are high and thin structures which are widely used at the industry and nuclear facilities. These structures are built on column elements as reinforced concrete. Determining the behavior of the buildings affected by the dynamic loads such as wind and earthquake is very important in terms of preventing the loss of life and property. In this study, hyperbolic cooling with 117m height tower was examined and the behaviors of the structure in earthquake and wind effects were investigated. During the application of the wind load, 25m / sec wind velocity was applied and three ground motion records were applied to the structures in the course of the earthquake analysis. The wind load was calculated in accordance with the ASCE 7-10 standard and it was given as angular. As a result of the analysis, the values of the displacement and stress were obtained and examined. According to the results of the wind load analysis; As the height of the tower increases, the values of wind load increase and the displacement values occurring in the building increase. The values of displacement and stress vary angularly depending on angular wind load. It is seen that the highest values of displacement and stress values were obtained in Kobe earthquake. Displacement values were examined depending on the height and the largest displacement values were obtained at the top part.

Keywords

References

  1. [1] Özgan K., Karakaş A. İ., Daloğlu A.T., Hiperbolik soğutma kulelerinin deprem analizi, Pamukkale Üniversitesi Müh. Bilim Dergisi, 22(6) (2016) 433-441.
  2. [2] Sabouri-Ghomi S., Kharrazi M. H. K., Javidan P. Effect of stiffening rings on buckling stability of RC hyperbolic cooling towers, Thin-walled structures, 44 (2) (2006) 152-158.
  3. [3] Busch D., Harte R., Krätzig W.B., Montag U. New Natural Draft Cooling Tower of 200m of height, J. Engineering Structures, 24 (2002) 1509-1521.
  4. [4] Zhao L., Ge Y., Kareem A., Fluctuating wind pressure distribution around full-scale cooling towers, Journal of Wind Engineering and Industrial Aerodynamics, 165 (2017) 34-45.
  5. [5] Karakaş A.İ., Elastik zemine oturan kule tipi yapıların SAP 2000–OAPI kullanılarak yapısal analizi ve optimum tasarımı, PhD Thesis, Karadeniz Technical University, The Graduate School of Natural and Applied Sciences, 2017.
  6. [6] Karakaş A.İ., Özgan K., Daloğlu A.T., A consistent FEM-Vlasov model for hyperbolic cooling towers on layered soil under unsymmetrical wind load, Wind and Structures, 22(6) (2016) 617-633.
  7. [7] Karakaş A.I., Özgan K., Daloğlu A. T., A Parametric study for free vibration analysis of hyperbolic cooling towers on elastic foundation using consistent FEM-Vlasov model., Arc Appl. Mech., 86 (2015) 869-882.
  8. [8] Ghomi S.S., Kharrazi M.H.K., Reinforced Concrete Column-Supported Hyperboloid Cooling Tower Stability Assessment for Seismic Loads., ScientiatIronica, 12(2) (2005) 241-246.

Details

Primary Language

English

Subjects

Engineering

Journal Section

Research Article

Publication Date

June 30, 2021

Submission Date

April 27, 2020

Acceptance Date

May 2, 2021

Published in Issue

Year 2021 Volume: 42 Number: 2

APA
Çarhoğlu, A. I. (2021). Investigation of behavior of cooling tower structure under external loads. Cumhuriyet Science Journal, 42(2), 465-475. https://doi.org/10.17776/csj.719940

Cited By

As of 2026, Cumhuriyet Science Journal will be published in six issues per year, released in February, April, June, August, October, and December