Electrochemical Behavior of Cholecalciferol on a Multiwalled Carbon Nanotube Modified Glassy Carbon Electrode
Abstract
Keywords
References
- [1] Højskov C.S., Heickendorff L., Møller H.J., High-Throughput Liquid–Liquid Extraction and LCMSMS Assay For Determination Of Circulating 25(OH) Vitamin D3 and D2 in the Routine Clinical Laboratory, Clin. Chim. Acta, 411 (2010) 114–116.
- [2] Kamankesh M., Mohammadi A., Mollahosseini A., Jazaeri S., Shahdoostkhany M., Vitamin D3 : Preconcentration and Determination in Cereal Samples Using Ultrasonic-Assisted Extraction and Microextraction Method, Cereal Chem. J., 94 (2017) 532–538.
- [3] Heaney R.P., Recker R.R., Grote J., Horst R.L., Armas L.A.G., Vitamin D3 Is More Potent Than Vitamin D2 in Humans, J. Clin. Endocrinol. Metab., 96 (2011) E447–E452.
- [4] Sklan D., Budowski P., Katz M., Determination of 25-Hydroxycholecalciferol by Combined Thin Layer and Gas Chromatography, Anal. Biochem., 56 (1973) 606–609.
- [5] Vanhaelen-fastré R., Vanhaelen M., High-Performance Liquid Chromatography Determination of Potential Content Of Vitamin D2 (Ergocalciferol) and Vitamin D3 (Cholecalciferol) in Resins, Oils, Dry Concentrates and Multivitamin Formulations, J. Chromatogr. A, 153 (1978) 219–226.
- [6] Takeuchi A., Okano T., Ayame M., Yoshikawa H., Teraoka S., Murakami Y., Kobayashi, T., High-Performance Liquid Chromatographic Determination of Vitamin D3 in Fish Liver Oils and Eel Body Oils., J. Nutr. Sci. Vitaminol., 30 (1984) 421–430.
- [7] Aksnes L., A Simplified High-Performance Liquid Chromatographic Method For Determination of Vitamin D3, 25-Hydroxyvitamin D2 and 25-Hydroxyvitamin D3 in Human Serum., Scand. J. Clin. Lab. Invest., 52 (1992) 177–182.
- [8] Mattila P., Piironen V., Bäckman C., Asunmaa A., Uusi-Rauva E., Koivistoinen P., Determination of Vitamin D3 in Egg Yolk by High-Performance Liquid Chromatography with Diode Array Detection, J. Food Compos. Anal., 5 (1992) 281–290.
Details
Primary Language
English
Subjects
-
Journal Section
Research Article
Authors
Şerife Eryılmaz Kahya
Türkiye
Mustafa Cittan
0000-0003-0377-5656
Türkiye
Ali Çelik
*
0000-0002-4676-1759
Türkiye
Publication Date
December 24, 2018
Submission Date
July 2, 2018
Acceptance Date
November 19, 2018
Published in Issue
Year 1970 Volume: 39 Number: 4
Cited By
High-Performance, Nitrogen-Doped, Carbon-Nanotube-Based Electrochemical Sensor For Vitamin D3 Detection
ACS Applied Bio Materials
https://doi.org/10.1021/acsabm.2c00094A manganese dioxide nanoparticle–bimetallic metal organic framework composite for selective and sensitive detection of vitamin D3 in human plasma
Microchimica Acta
https://doi.org/10.1007/s00604-023-05904-xAn Antibody-Free, Silver-Silver Oxide-Carbon Nanotube Nanocomposite-Based Impedimetric Sensor for the Nanomolar Detection of 25-Hydroxyvitamin D3
Journal of The Electrochemical Society
https://doi.org/10.1149/1945-7111/acef5cElectrochemical Determination of Vitamin D3 in Pharmaceutical Products by Using Boron Doped Diamond Electrode
Electroanalysis
https://doi.org/10.1002/elan.201900532Fabrication of handmade paper sensor based on silver-cobalt doped copolymer-ionic liquid composite for monitoring of vitamin D3 level in real samples
Microchemical Journal
https://doi.org/10.1016/j.microc.2020.105789Synthesis and characterization of novel lanthanum nanoparticles-graphene quantum dots coupled with zeolitic imidazolate framework and its electrochemical sensing application towards vitamin D3 deficiency
Colloids and Surfaces A: Physicochemical and Engineering Aspects
https://doi.org/10.1016/j.colsurfa.2020.125854Electrochemical vitamin sensors: A critical review
Talanta
https://doi.org/10.1016/j.talanta.2020.121645Evaluating the origin of the electrocatalytic activity of multiwalled carbon nanotubes towards Vitamin D3 oxidation
Journal of Electroanalytical Chemistry
https://doi.org/10.1016/j.jelechem.2022.116215Preparation of mesoporous carbon containing Polyurethane/Clay nanocomposite membrane based sensors for sensitive and selective determination of vitamin D2 in urine samples
Measurement
https://doi.org/10.1016/j.measurement.2022.111979