Conference Paper

Evaluation of dosimetric impact of Flattening Filter-Free (FFF) Photon Beams in 3D conformal radiotherapy

Volume: 39 Number: 1 March 16, 2018
EN TR

Evaluation of dosimetric impact of Flattening Filter-Free (FFF) Photon Beams in 3D conformal radiotherapy

Abstract

Flattening Filter Free (FFF) photon beams have been frequently used in radiotherapy clinical practice. This study aimed to analyze the dosimetric quality of the FFF beams, as compared to the standard flattened beams (FB) for plans of treatment of three patients involving three cancer sites using the 6 and 10 MV photon energies and the 3D conformal radiotherapy technique (3D-CRT). The doses to the planning target volumes (PTVs) and organs at risk (OARs) were compared. The dose-volume histogram curves analysis show that no significant differences between FFF and FB plans were found in the coverage and mean dose for the PTV, the OAR revealed slight differences. So the FFF photon beam achieved comparable dosimetric quality as the standard flat beam.

Keywords

References

  1. [1]. Podgorsak E.B, Radiation Oncology Physics: A Handbook for Teachers and Students. International Atomic Energy Agency, 2005.
  2. [2]. Fogliata A & al, Definition of parameters for quality assurance of flattening filter free (FFF) photon beams in radiation therapy, J. Med. Phys, 39 (2012) 6455- 64.
  3. [3]. Rout BK, Muralidhar KR, Ali M, Shekar MC and Kumar A, Dosimetric study of RapidArc plans with flattened beam (FB) and flattening filter-free (FFF) beam for localized prostate cancer based on physical indices. Int. J. Cancer Ther. Oncol., 2 (2014) 2046.
  4. [4]. M. Kretschmer & al, The impact of flattening-filter-free beam technology on 3D conformal RT, J. Radiat Oncol., 8 (2013) 133.
  5. [5]. Stathakis S and al, Treatment planning and delivery of IMRT using 6 and 18 MV photon beams without flattening filter. Applied Radiation and Isotopes, 67 (2009) 1629-37
  6. [6]. Mingzan Z and al, Volumetric modulation arc radiotherapy with flattening filter-free beams compared with conventional beams for nasopharyngeal carcinoma: a feasibility study, Chin. J. Cancer, 32 (2013) 397-402.
  7. [7]. Stevens S.W, Rosser K.E, and Bedford J.L, A 4 MV flattening filter free beam: Commissioning and application to conformal therapy and volumetric modulated arc therapy, J. Phys Med Biol., 56 (2011) 3809-24.
  8. [8]. Scorsetti M and al, Feasibility and early clinical assessment of flattening filter free (FFF) based stereotactic body radiotherapy (SBRT) treatments, J. Radiat Oncol., 6 (2011) 113.

Details

Primary Language

English

Subjects

-

Journal Section

Conference Paper

Authors

Fatima Benrachı
Algeria

Publication Date

March 16, 2018

Submission Date

November 30, 2017

Acceptance Date

January 31, 2018

Published in Issue

Year 1970 Volume: 39 Number: 1

APA
Kourtelı, C., & Benrachı, F. (2018). Evaluation of dosimetric impact of Flattening Filter-Free (FFF) Photon Beams in 3D conformal radiotherapy. Cumhuriyet Science Journal, 39(1), 196-200. https://doi.org/10.17776/csj.359904

As of 2026, Cumhuriyet Science Journal will be published in six issues per year, released in February, April, June, August, October, and December